MOPORI11 Seismic Analysis for Safety Requirements of SPIRAL2 Accelerator 252
 
  • C. Barthe-Dejean, F. Lutton, M. Michel
    GANIL, Caen, France
 
  The SPIRAL2 Accelerator at GANIL is a superconducting ion continuous wave LINAC with two associated experimental areas. Mechanical engineers have been highly involved in the design of SPIRAL2 equipments since the beginning of the project in 2004. During the development phase, Computer Aided Design and calculation codes have been used throughout the complete process : from the ion sources, the LINAC, the beam transport lines and the experimental halls equipped with detectors. SPIRAL2 has to meet different safety requirements, among which seismic hazard. This involves justifying that the integrity of the radiologic containment barrier is always maintained in case of earthquake. This paper reports the improvement in design and calculation methods performed by GANIL engineers to meet the seismic safety requirements, specificly the non-missility feature of the equpiment. The modal-spectral simulations, used to demonstrate the mechanical strength of equipments in case of earthquakes, was an important part of this design activity in the past 10 years New methods have been used to calculate welds, fasteners and the ground anchor of the structural supports of the heaviest equipments.
C. Barthe-Dejean, F. Lutton, « Guide methodologique pour Calculs de Tenue aux Séismes des équipements mécaniques », Note STP-535-A
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2022-MOPORI11  
About • Received ※ 14 August 2022 — Revised ※ 19 August 2022 — Accepted ※ 30 August 2022 — Issue date ※ 02 September 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPORI12 Development of Commercial RFQ Toward CW Applications 255
MOOPA08   use link to see paper's listing under its alternate paper code  
 
  • H. Yamauchi, M. Masuoka
    Time Corporation, Hiroshima, Japan
 
  TIME Co. developed a new 4-vane RFQ structure that can be used for a very high-duty factor operation. We eliminated the tuners to flatten the field distribution. The tuners increase RF contacts which may trigger unex-pected local heat spots and subsequent discharges. In addition, we hollowed out the entire vane to achieve large cooling water channels. A high-power test showed that the commissioning was completed within one day. We could input a nominal RF power without experienc-ing almost any discharge. The applied duty factor was 5 % at the 200 MHz resonant frequency, and the meas-ured frequency shift was not detected.
These activities have been carried out in collaboration with Tokyo Institute of Technology and RIKEN.
 
slides icon Slides MOPORI12 [1.877 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-LINAC2022-MOPORI12  
About • Received ※ 26 August 2022 — Revised ※ 04 September 2022 — Accepted ※ 27 September 2022 — Issue date ※ 29 September 2022