Three Years of Operation of the SPIRAL2 SC LINAC- RF Feedback |
98 |
|
- M. Di Giacomo, M. Aburas, P.-E. Bernaudin, O. Delahaye, A. Dubosq, A. Ghribi, J.-M. Lagniel, J.F. Leyge, G. Normand, A.K. Orduz, F. Pillon, L. Valentin
GANIL, Caen, France
- F. Bouly
LPSC, Grenoble Cedex, France
- S. Sube
CEA-DRF-IRFU, France
|
|
|
The superconducting LINAC of SPIRAL2 at the GANIL facility has been in operation since October 2019. The accelerator uses 12 low beta and 14 high beta supercon-ducting quarter wave cavities, cooled at 4°K, working at 88 MHz. The cavities are operated at a nominal gradient of 6.5 MV/m and are independently powered by a LLRF and a solid-state amplifier, protected by a circulator. Pro-ton and deuteron beam currents can reach 5 mA and beam loading perturbation is particularly strong on the first cavities, as they are operated at field levels much lower than the nominal one. This paper presents a feedback after three years of oper-ation, focuses on the RF issues, describing problems and required improvement on the low level, control and pow-er systems
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2022-MOPOPA15
|
|
About • |
Received ※ 14 August 2022 — Revised ※ 17 August 2022 — Accepted ※ 01 September 2022 — Issue date ※ 02 September 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPOGE02 |
Three Years of Operation of the SPIRAL2 LINAC: Cryogenics and Superconducting RF Feedback |
479 |
|
- P.-E. Bernaudin, M. Aburas, M. Di Giacomo, A. Ghribi, P. Robillard, L. Valentin
GANIL, Caen, France
|
|
|
The superconducting LINAC of SPIRAL2 at the GANIL facility is in operation since October 2019. Its 26 super-conducting quarter wave resonating cavities (88 MHz) are operated at a nominal gradient of 6.5 MV/m, but most of the cavities can be operated up to 8 MV/m. They are integrated into 19 cryomodules and cooled down at 4 K by a dedicated refrigeration cryogenic system. In this paper, we will present a feedback after five years of operation of the cryogenic system, focusing on the main problems that have been faced, and on the diverse evolutions performed in order to improve the cryogenic system and to increase its reliability. We will also provide a feedback of the superconducting cavities performances status after three years of operation
|
|