Paper |
Title |
Page |
MOPOJO07 |
Experimental Study to Optimize the Treatment Efficacy of Pharmaceutical Effluents by Combining Electron Beam Irradiation |
38 |
|
- P. Kumar, A.B. Kavar, M. Meena, P. Nama, A. Pathak, R. Varma
IIT Mumbai, Mumbai, India
- A.P. Deshpande, T.S. Dixit, R. Krishnan
SAMEER, Mumbai, India
|
|
|
Here, we report our first step towards tackling this issue at the roots by irradiating the pharmaceutical effluents from a stages of their existing treatment plant with an Electron Beam (EB) with doses varying from 25 kGy to 200 kGy. We have used a normal conducting pulsed wave linear accelerator developed by SAMEER. It produced a pencil beam of electrons of energy 6 MeV with an average current of 16 micro-Ampere. To ensure optimum dose delivery, Fluka-Flair Simulations have been used. We have successfully demonstrated that electron beam irradiation along with the use of conventional techniques like coagulation after the irradiation can further increase the efficacy of the process with a final reduction in Chemical Oxygen Demand (COD) to be as large as 65% in some of the cases.
|
|
|
Poster MOPOJO07 [0.745 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2022-MOPOJO07
|
|
About • |
Received ※ 17 August 2022 — Revised ※ 21 August 2022 — Accepted ※ 26 August 2022 — Issue date ※ 01 September 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
MOPOJO08 |
RF Design, Optimization and Multiphysics Study of a β = 1, 1.3 GHz Single Cell Accelerating Cavity for High-Intensity Compact Superconducting Electron Accelerator (HICSEA) |
41 |
SUPCGE06 |
|
|
- M. Meena, A. Pathak, R. Varma
IIT Mumbai, Mumbai, India
|
|
|
High-energy electron accelerators have been used in water purification for several years. They are very effective for the removal of complex impurities. This study aims to design a superconducting electron beam accelerator with an output energy of 1 MeV and beam power of 40 kW for wastewater treatment. A 1.3 GHz single cell elliptic cavity with β = 1 was designed and optimized for TM010 mode and an accelerating gradient of 15 MV/m. For the optimized cavity, the RF parameters, namely, R/Q, transit time factor and geometry factor (G) were found to be 174.93 ohm, 0.67 and 276 ohm, respectively. Multiphysics studies showed that the value of R/Q for fundamental accelerating mode was 174.93 ohm. It was much higher than that of other modes, thus, HOM coupler is not required for the system. The Lorentz force detuning coefficient after stiffening the cavity iris, and the temperature rise due to the RF surface losses were found to be 0.20 Hz/(MV/m)2 and 0.085 K, respectively. It is also observed that there is no occurrence of multipacting for the designed accelerating gradient.
|
|
|
Poster MOPOJO08 [1.584 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-LINAC2022-MOPOJO08
|
|
About • |
Received ※ 24 August 2022 — Revised ※ 26 August 2022 — Accepted ※ 01 September 2022 — Issue date ※ 05 September 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,